Transmitting
This section describes how to configure and key up the SRX-8 transmitter.
To key up the transmitter, set tx.enable to true and wait approximately 1 second
for the transmitter to complete the key up sequence.
By default, the SRX-8 transmitter will emit dummy PLFRAMEs if no user data is supplied to the transmitter. Dummy PLFRAMEs are described in [ETSI_EN] section 5.5.1.
Modifying tx.freq, tx.rate or tx.pout will automatically trigger a key down
followed by a key up if the transmitter is already transmitting. It is recommended
to configure these prior to setting tx.enable to true.
An example of how to configure and key up the transmitter is shown below:
[srx-8] prop set tx.pout 30
[srx-8] prop set tx.rate 150000000
[srx-8] prop list tx
Property Type Stat Flag Value
enable bool D NR false
freq u64 D - 8200000000 hz
rate u32 D - 150000000 baud
rolloff u8 D - 0
goldseq u32 D - 0
pout flt D - 30.00 dBm
pa.templimit u8 D - 80
bbframes u64 M NR 0 frames
pwr.fwd flt M NR 0.00 dBm
pwr.rfl flt M NR 0.00 dBm
volt.vga.vc u16 M NR 0 mV
volt.drv.vg i16 M NR -2049 mV
volt.pa.vg i16 M NR -3999 mV
gain flt M NR 0.00 %
[srx-8] prop set tx.enable true
<Wait a second>
[srx-8] prop list tx
Property Type Stat Flag Value
enable bool M NR true
freq u64 D - 8200000000 hz
rate u32 D - 150000000 baud
rolloff u8 D - 0
goldseq u32 D - 0
pout flt M - 30.00 dBm
pa.templimit u8 D - 80
bbframes u64 M NR 0 frames
pwr.fwd flt M NR 29.94 dBm
pwr.rfl flt M NR 23.63 dBm
volt.vga.vc u16 M NR 2035 mV
volt.drv.vg i16 M NR -1149 mV
volt.pa.vg i16 M NR -3082 mV
gain flt M NR 29.56 %
The transmitter is now transmitting dummy PLFRAMEs. See IP Forwarding and BBFRAME Data Service for more information on how to supply payload data to the transmitter.
Idle BBFRAMEs
Some DVB-S2 receiver equipment requires BBFRAMEs with idle data instead of dummy PLFRAMEs in order to lock.
To transmit idle BBFRAMEs, set the enable property in the idle property group to true.
This will generate a generic continuous stream (TS/GS = 01) of zero-length (DFL = 0)
BBFRAMEs, which will fill the link whenever it is not fully utilized. The properties in the ìdle
table can be used to modify the idle BBFRAME format. Refer to Idle BBFRAME Generator Group, BBFRAME Data Service
and [ETSI_EN] section 5 for more details.